Set Home Add to Favorites Contact Us
中文 | English   
Home | About HNAC | Products | Quality | Achievement | Latest News | Join us | Contact us
 
 
 
Your position:Products Expo

 
 

Power Plant Integrated Automation System
 



(Click to enlarge)
Sphere of application:
 Automatization function of hydropower station, thermal-electric plant control, protection, measure, signal, remote sight and
Standard Configuration:
(1)Protection function
◆ Generator differential protection (vertical and horizontal )
◆ Three zone multi-voltage closedown over-current protection
◆ Negative sequence over-current protection
◆ Over/low voltage protection
◆ Rotor single-point/two-point ground protection
◆ Reverse power protection (steam-turbine generator)
◆ Loss of excitation protection
◆ Over load alarm
◆ Unbalance voltage protection (steam-turbine generator)
◆ Zero sequence over voltage protection
◆ High-frequency protection
◆ Low-frequency protection
◆ Non-electrical protection
◆ Others (depend on the users)

(2) Telemtering function:

    All electric quantity use Fourier Algorithm to do AC sampling directly by high accuracy small PT and CT, which has high sampling accuracy and can measure the parameter of loop U, I, P, Q, COS, F, kWh, kvarh and so on. And it can display measured primary actual value and accept measured value of transformer and axletree temperature from temperature transducer, and measure value of press, flux, water lever from transducer.

(3) Remote signal function:
 
◆ External remote signal: Switch signal such as switch position, breaker position, manual-switch position, accumulated energy status, generator state, auxiliary devices status and so on.
◆ Accident remote signal: Electric accident signal of differential, over voltage, lose-excitation,quick breaking, overcurrent, heavy gas and others. Generator accident signal of axletree overtemperature and low oil press.
◆ Fault signal: Signal of over-load, slight gas, high-temperature, earthed, control loop break, axletree high-temperature, cooling water break.
◆ State of remote signal: Signal of protecting action, abnormal unit, remote signal changing, device reset. The type of remote signal can be set freely (locale configuration).

(4) Remote control function:

    Breaker trip/close, generator start/stop automatically, vane-opening increase/decrease, rotate speed up/down, sluice gate and valve control.
Integrated automation system convergence arrangement illustrate:


(Click to enlarge)
MTC-3
  DMP300 Series Integrative Protection Monitor Device
  Transformer Substation Integrated Automation System
  Power Plant Integrated Automation System
  Integrated Automation Remote Monitor System
PSJ-01
  Generator Automatization Panel
PWL-2A
  Microcomputer Excitation Device
YWT/WCT
  Hydraulic Microcomputer Speed Regulator
PZL-03
  High Frequency Switching DC Power Supply System
MTC- DD
  Power Grid Automatic Dispatching System
KYN/GCK/ZBW
  Distribution Transformer and Transformer Substation Equipments
HBO
  HBO Distributed Control System(DCS)

Address:Lusong Rd, Lu Valley National High-tech Industrial Development Zone, Changsha, Hunan Province, China | Post Code:410205 | Central Exchange:0731-8238888 | Fax:0731-8907777 | Reception Tel:0731-8906888 |
Marketing Tel:0731-8906666 | Service Tel: 0731-8905555 | Complain Tel:0731-6622222 |
Website:http://www.cshnac.com |  Email:cshnaclt@126.com
Copyright © 2005 Changsha Huaneng Automatic Control GroupAll Rights Reserved